Please use this identifier to cite or link to this item: http://sgc.anlis.gob.ar/handle/123456789/2547
Title: UV/solar photo-degradation of furaltadone in homogeneous and heterogeneous phases: Intensification with persulfate
Authors: Durán, Antonio 
Montegudo, José María 
Castillo, D 
Expósito, Antonio J 
Keywords: Energía Solar;Titanio;Purificación del Agua
Issue Date: 1-Oct-2022
Journal: Journal of environmental management 
Series/Report no.: J Environ Manage;2022(319):115712
Abstract: 
Previous studies on removal of the pharmaceutical drug Furaltadone (FTD) in water have not shown to be totally efficient or are very expensive. In this study, sulfate radicals derived from persulfate anions activated with different irradiation sources (UVA, UVC and solar light) and combined with H2O2 and/or TiO2 have been tested in homogeneous and heterogeneous phases under different operation modes and reaction systems. In homogeneous phase, UV produces a slow mineralization (k = 0.0013 min-1). The combined processes are faster (kUV/H2O2 = 0.0185 min-1, kUV/PS = 0.0206 min-1) with the best performance for the UV/PS system yielding nearly 80% of mineralization in half an hour. The overall process (UV/H2O2/PS) does not show synergy and mineralization is even slower (kUV/H2O2/PS = 0.015 min-1) due to the production of a high amount of radicals favouring unproductive reactions (scavenger effect). A mineralization mechanism is proposed involving formation of 5hydroxymethylene-2(5H)-furanone and NO as the main intermediates. In heterogeneous phase (UVA/TiO2/PS), the holes play an important role changing the mineralization mechanism. The main intermediates formed were C12H17N4O4 and C11H14N3O4, which rapidly were degraded to form C8H15O3N3, C4H10NO and C5H10NO. An economic study of operation costs has been made for selected processes: UVC/PS, UVA/TiO2/PS and Solar/TiO2/PS. The Solar/TiO2/PS process has the lowest operation costs due to the use of solar energy. However, it would need an additional stage to recover the catalyst. Finally, a loss of 27% in efficiency during mineralization was found after 5 cycles, but the catalyst recovers its initial performance after regeneration at 500 °C.
Description: 
Fil: Durán, Antonio. Department of Chemical Engineering, Grupo IMAES. ETSII, Instituto de Investigaciones Energéticas y Aplicaciones Industriales (INEI), Universidad de Castilla-La Mancha; España

Fil: Montegudo, José María. Department of Chemical Engineering, Grupo IMAES. ETSII, Instituto de Investigaciones Energéticas y Aplicaciones Industriales (INEI), Universidad de Castilla-La Mancha; España

Fil: Castillo, D. Department of Chemical Engineering, Grupo IMAES. ETSII, Instituto de Investigaciones Energéticas y Aplicaciones Industriales (INEI), Universidad de Castilla-La Mancha; España

Fil: Expósito, Antonio J. Department of Chemical Engineering, University of Bath; Reino Unido
URI: http://sgc.anlis.gob.ar/handle/123456789/2547
DOI: 10.1016/j.jenvman.2022.115712
Appears in Collections:Artículos

Show full item record

Page view(s)

33
checked on Apr 20, 2024

Google ScholarTM

Check

Altmetric

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.